Control Panel Area Wide Parameters | en 97
Bosch Security Systems, Inc. Program Entry Guide 2017.03 | 09 | F.01U.303.998
Notice!
Keypads assigned to Associate areas, when used with Shared areas, must have Keypad Scope
programmed.
– Shared - shared areas cannot be armed using a passcode, keyswitch, Sked or by the RPS.
The scope of all Associate areas must include the Shared area(s) in order to view faulted
points. Shared areas:
– Are not associated to other areas by account number, they are shared panel wide.
– Are armed when all Associate areas in the control panel are put into All On Delay
state.
– Are disarmed when at least one Associate area in the control panel is taken out of All
On Delay state.
Notice!
Arming commands intended for a Shared area must be executed on a keypad with Panel Wide
scope by a user with appropriate authority in all Associate areas. Shared areas associate with
all Associate areas regardless of their account assignments. The shares area does not begin to
arm until all Associates finish arming.
Shared Area Characteristic Description
Arming a Shared Area Requires all Associate areas to be armed. As
soon as the last Associate area is armed, the
Shared area begins its arming sequence
automatically. Shared areas cannot be armed
by passcode, keyswitch or RPS. To allow
faulted points to be displayed at associated
areas, the shared and associate areas must
share the same account number.
Disarming a Shared Area Shared areas automatically disarm when any
Associate area in the control panel is
disarmed. Shared areas cannot be disarmed
by passcode, cards, keyswitch or RPS.
Shared Area Arming Sequence When Shared areas automatically begin to
arm, the arming is based on the A# Exit Dly
Time programmed for the Area # where the
keypad has been assigned.
Shared Area Not Ready If a point is faulted in the Shared area,
[CHECK AREA] will display on the Associate
keypad that is arming the last Associate area.
Associate area keypads can display faults
from Shared areas as long as the Shared
areas fall within the scope of the Associate
area.