Commands for Error and Status
Requests
/ERRFLAG /ACT R / W NONE,
POWER,
STANDBY,
PROTECT,
OVT,
GNDFLT_A,
GNDFLT_B,
ZMIN_A,
ZMIN_B,
ZMAX_A,
ZMAX_B,
PILOT_A,
PILOT_B,
PRE- SET,
PCDUMP,
DIRTY,
PWR-
GOOD,
CAN-
POLL,
BRIDGED,
COLLECT,
GLOBAL,
MEAS,
Z_VLD_A,
Z_VLD_B,
EEPROM,
PRSGATE,
PLT_IN_A,
PLT_OUT_A
, PLT_IN_B,
PLT_OUT_B
List of currently set status and error
flags.
Writing resets the flags GNDFLT_A,
GNDFLT_B, COLL- ECT, GLOBAL,
PRSGATE.
/COLLECT R / W Flag template for Collected Error Flag
(a list of status and error flags as
mentioned above).
The state is buffered (Hold function)
when COLLECT is listed in the
template.
/GLBMASK R / W NONE,
0...255
Template for monitoring GLOBAL
status and error flags of external CAN
devices.
/GLOBAL R NONE,
0...255
List of external CAN devices with set
GLOBAL status and error flags.
IRIS-Net REMOTE AMPLIFIER | en 161
Bosch Security Systems B.V. User Manual 2017.05 | 3.20 | F.01U.119.956