FIR-Filter Design
Element Default Range Description
ORDER of the FIR filter.
1600 Hz 20 to 19999
Hz
HI PASS sets the cut-off frequency of the Hi pass filter.
16 kHz 21 to 20000
Hz
LO Pass sets the cut-off frequency of the Lo pass filter.
40 dB 21 to 100 dB STOP RIPPLE sets the slope of the FIR filter.
Band Pass Allows selection of the FIR filter type of the corresponding
output channel.
Press this button to generate the FIR filter.
OUTPUT DELAY
Individual output delays can be set for each output channel of the power amplifier.
HINT: The power amplifiers output delays can be used to compensate for the positioning of cabinets or speaker
arrays relative to each other or the original sound source, for example aligning the PA to the stage or aligning the
full-range loudspeakers to the subwoofers. The Output Delay parameter determines the delay time of the
corresponding channel or the distance between different loudspeaker clusters.