The Debounce block is used for debouncing the Boolean value at the input. The
debounce time is adjustable. Following chart illustrates the functionality of the
available block parameters. One key function of the debounce block is that if the input
changes from false to true and then back to false again before the debounce time has
elapsed then the output will not be set to true.
The Analog Delay block is used for delaying rational numbers at the input. The value at
the input will not be sent to the output until the delay time has elapsed. The maximum
delay time is 20 seconds.
The Logic Delay block is used for delaying Boolean values at the input. The value at the
input will not be sent to the output until the delay time has elapsed. The maximum
delay time is 20 seconds.
The Text Box allows labeling the task engine configuration. Click the Modify Properties
entry in the context menu to open the Edit Textbox dialog. This dialog allows editing
the caption and e.g. font size and font type.
Superblocks Superblocks are listed here. Please refer to page 240 how to use Superblocks.
IRIS-Net DIGITAL MATRIX | en 338
Bosch Security Systems B.V. User Manual 2017.05 | 3.20 | F.01U.119.956

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch IRIS-Net and is the answer not in the manual?

Bosch IRIS-Net Specifications

General IconGeneral
BrandBosch
ModelIRIS-Net
CategorySecurity System
LanguageEnglish

Related product manuals