Commands for Compressor
Read
Write
Values
Description
/
PARA
M
/DSP /
COMPRESS
OR_x
/ATTACK /
VALU
E
R / W 5...150 Attack time in ms
/BYPASS /
VALU
E
R / W 0, 1 0 = Bypass not activated, 1 =
Bypass activated
/
GAINREDU
CTION
/
VALU
E
R Gain reduction as full scale value
(32 bit) Transform given value
into dB by: 20 log (0x7FFFFF/
value)
/
MAKE_UP_G
AIN
/
VALU
E
R / W -18...6 Gain of compressor output in
dB, not available for RCM24
compressor
/RATIO /
VALU
E
R / W 1...100 Compressor ratio
/RELEASE /
VALU
E
R / W 10...1000 Release time in ms
/SOFTKNEE /
VALU
E
R / W 0...20 Soft knee in dB, not available for
RCM24 compressor
/
THRESHOL
D
/
VALU
E
R / W -9...21 Threshold in dB
Commands for Delay
Read
Write
Values
Description
/
PARA
M
/DSP /
DELA
Y_x
/BYPASS /VALUE R / W 0, 1 0 = Bypass not activated, 1 =
Bypass activated
IRIS-Net DIGITAL MATRIX | en 465
Bosch Security Systems B.V. User Manual 2017.05 | 3.20 | F.01U.119.956