Commands for Limiter
Read
Write
Values
Description
/
PARA
M
/DSP /
LIMITER_x
/ATTACK /VALUE R / W 0...50 Attack time in ms
/BYPASS /VALUE R / W 0, 1 0 = Bypass not activated, 1 =
Bypass activated
/
GAINREDU
CTION
/VALUE R Gain reduction as full scale value
(32 bit)
Transform value into dB by: 20
log (0x7FFFFF/ value)
/RELEASE /VALUE R / W 10...1000 Release time in ms
/
THRESHOL
D
/VALUE R / W -9...21 Threshold in dB
Commands for Loudspeaker Controller
Read
Write
Values
Description
/
PARA
M
/DSP /
LSPKBLO
CK_x
/CHn /
COMPRESSO
R.ATTACK
/VALUE R / W 5...50 Attack time in ms.
/
COMPRESSO
R.BYPASS
/VALUE R / W 0, 1 0 = Bypass not
activated, 1 = Bypass
activated
/
COMPRESSO
R.GAINREDU
CTION
/VALUE R Gain reduction as full
scale value (32 bit)
Transform value into
dB by: 20 log
(0x7FFFFF/ value)
/
COMPRESSO
R.RATIO
/VALUE R / W 1...8 Compressor ratio
/COMPRES-
SOR.RELEAS
E
/VALUE R / W 50...999 Release time in ms
/
COMPRESSO
R.THRESHOL
D
/VALUE R / W -9...21 Threshold in dB
IRIS-Net DIGITAL MATRIX | en 474
Bosch Security Systems B.V. User Manual 2017.05 | 3.20 | F.01U.119.956