The following table lists the ASCII Control Protocol commands with brief explanations.
Ebene1
Ebene2
Ebene3
Ebene4
Rea
d
Writ
e
Values
Description
Commands for RS232 communication
/COMM /LINEFEED R /
W
ON, OFF Linefeed Status for RS232
communication
/PROMPT R /
W
ON, OFF Prompt Status for RS232 communication
/ECHO R /
W
ON, OFF Echo Status for RS232 communication
Commands for device front
/FRONT /CONTRAST R /
W
-10 to +10 Contrast of displays
/
BRIGHTNESS
R /
W
0 to 10 Brightness of displays
/INTENSITY R /
W
0 to 10 Brightness of LEDs
/VU /MODE R /
W
FAST, SLOW,
PEAK
Mode of VU meter
/REF R /
W
CLIP, LIMIT Reference for VU meter
/SAVER R /
W
ON, OFF State of screen saver
Commands for Control Port
/
CONTR
OL
/PINS R 0, 1 State of control inputs (1 = open, 0 =
closed)
/STATE R Indicates the highest number of all
control inputs with state „0“.
/PORT1 R /
W
Preset to be loaded when Port 1 is
closed.
... R /
W
/PORT5 R /
W
Preset to be loaded when Port 5 is
closed.
IRIS-Net DIGITAL SOUND PROCESSOR | en 695