Element
Description
The current condition of each type of error gets indicated. Green means no error, red
indicates that an error has been detected.
At the occurrence of a type of error for which the checkbox DETECT is ticked, the
COLLECTED ERROR: DCS DEVICES flag is set at the same time.
DEVICE CONNECTED The CAN bus connection between DPM and DCS is broken.
MEMORY Memory or Read/Write error.
WATCHDOG Watchdog error in DCS. This error type is logged according standards, press the CLEAR
button to reset the error.
FIRMWARE The firmware version of the DCS is not compatible with the DPM firmware version. A
firmware update is recommended.
DCS MODULES The module configuration of the DCS in IRIS-Net does not match the actual module
configuration.
POWER SUPPLY Supply voltage out of range.
COLLECTED ERROR: DCS
DEVICES
The state of this error is forwarded to the DPM 8016, see Supervision Dialog, page 727.
Press this button to activate the COLLECTED ERROR: DCS DEVICES manually.
IRIS-Net PROMATRIX 8000 | en 833
Bosch Security Systems B.V. User Manual 2017.05 | 3.20 | F.01U.119.956