NOTIFICATON At the occurrence of a type of error for which the checkbox DETECT is ticked, the
COLLECTED ERROR STATE flag is set at the same time. Additionally the FAULT
indicator light on the front panel of the controller lights, the FAULT relay opens
and a signal sound.
CONTROLS
Error types
DEVICE
CONNECTED
CAN connection between Controller and Amplifier broken.
MEMORY Memory error.
WATCHDOG Watchdog error of the device. This error type is logged conforming to standards,
press the CLEAR button to reset the error.
FIRMWARE The firmware version is not compatible with the IRIS-Net version used. A firmware
update is recommended.
PROTECT Protect mode of amplifier activated.
OVERHEAT Temperature overload of the device.
POWER SUPPLY
MAINS
Error in the mains power supply of the device.
POWER SUPPLY
BATTERY
Error in the battery power supply of the device.
OUTPUT PILOT
DETECTION
Missing pilot tone at the amplifier output channel 1 or 2.
INPUT x PILOT
DETECTION
Missing pilot tone at the amplifier input channels 1 to 4.
MASTER
COMBINED FAULT
STATE
The FAULT indicator light on the front panel of the device lights at the occurrence of this type
of error.
Manually setting or resetting an error.
IRIS-Net PROMATRIX 6000 | en 910
Bosch Security Systems B.V. User Manual 2017.05 | 3.20 | F.01U.119.956