53-1002177-19 Hardware Installation Guide
Brocade DCX 8510-4 Backbone Hardware Installation Guide
7. ficonshow switchrnid (FICON/mainframe environments only)
8. configupload
The factory serial number and the sequence number in the following outputs should match, except in the ficonshow
switchrnid, which will have a number appended to the front indicating that the logical switch number, if virtual fabrics
is enabled:
switch:FID128:admin> chassisshow
<output truncated>
WWN Unit: 1
Header Version: 2
Power Consume Factor: -1
Factory Part Num: 60-1000491-05
Factory Serial Num: AFX2533G001
Manufacture: Day: 19 Month: 1 Year: 2012
Update: Day: 5 Month: 5 Year: 2014
Time Alive: 756 days
Time Awake: 3 days
WWN Unit: 2
Header Version: 2
Power Consume Factor: -1
Factory Part Num: 60-1000491-05
Factory Serial Num: AJX0416G02H
Manufacture: Day: 12 Month: 8 Year: 2011
Update: Day: 5 Month: 5 Year: 2014
Time Alive: 897 days
Time Awake: 3 days
Chassis Factory Serial Num: AFY2530G00S
switch:admin> ficonshow switchrnid
{
{Switch WWN Flag Parm
10:00:00:05:1e:95:b1:00 0x00 0x200a00
Type number: SLKWRM
Model number: DCX
Manufacturer: BRD
Plant of Manufacture: CA
Sequence Number: 0AFX2533G001
tag: b6ff
}
5. If performing the power-down replacement procedure, perform the following steps. If hot-swapping WWN cards, skip to
step 6.
a) Log in to the chassis and execute the switchcfgpersistentdisable command on the main switch and other
logical switches. The switchcfgpersistentdisable command disables the switches, and ensures they remain
disabled after the power is cycled. This allows you to check all the settings so that you can verify the settings
before placing the chassis back into production.
switch:admin> switchcfgpersistentdisable
Switch's persistent state set to 'disabled'
53-1002177-19
132