53-1002177-19 Hardware Installation Guide
Brocade DCX 8510-4 Backbone Hardware Installation Guide
Issue Possible cause Recommended action
The device was rebooted while an WWN
card was uninstalled or failed.
Initial setup results in IP address/Domain ID
conflict.
The device was connected to the fabric
before being configured.
Refer to the Brocade Fabric OS
Administration Guide for configuration
information.
The device might be booting or running
POST.
Verify that boot and POST are complete.
The device requires a minimum of 3
minutes, usually, after power-on to
complete POST.
Beaconing might be on for the entire device
or for individual components.
Determine whether beaconing is on by
typing the switchShow command and
determine whether switch beaconing or
blade beaconing are on.
Individual components might have failed. Refer to the LED tables in the "System
Monitoring" section for interpretation and
recommended actions.
LEDs on one or more components are
changing rapidly or do not indicate a
healthy state.
Pins on the components might be
damaged.
Remove the component from the chassis
and inspect the pins on the component and
inside the chassis. Do not reinstall if pins
on either component are damaged, as this
could damage pins on other components.
Replace the parts as required.
Component might not be seated correctly. Ensure that the device has power and
the component is firmly seated. If the
problem continues, enter the sensorShow
command to determine the component
status. If the component is a CP blade or
port blade, enter the slotShow command
to determine the status.
None of the LEDs on a component are on.
Component might have failed. Replace the component as necessary.
There is excessive serial port activity. Ensure that the serial port activity remains
below specified amount.
CP blade is attached to an Ethernet with
high traffic loads.
Ensure that the Ethernet traffic remains
below specified amount
CP blades are failing over frequently.
Chassis is overheated. Enter the tempshow and sensorShow
commands to check internal temperature.
If components are overheating, shut down
port blades as necessary to return the
temperature to operating range. Also try
moving the blades in the chassis because
it is possible that airflow might not be
adequate to cool everything in certain
configurations.
One or more port blades have either shut
down or failed POST as indicated by the
error log.
Blades might be overheated. Enter the sensorShow command to
check the internal temperature readings.
If components are overheating, shut down
port blades as necessary to return the
temperature readings to the operating
ranges. Also try moving the blades in the
chassis because it is possible that airflow
might not be adequate to cool everything in
certain configurations.
53-1002177-19
163
Broadcom

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Broadcom Brocade DCX 8510-4 Backbone and is the answer not in the manual?

Broadcom Brocade DCX 8510-4 Backbone Specifications

General IconGeneral
BrandBroadcom
ModelBrocade DCX 8510-4 Backbone
CategoryNetwork Hardware
LanguageEnglish