53-1002177-19 Hardware Installation Guide
Brocade DCX 8510-4 Backbone Hardware Installation Guide
Issue Possible cause Recommended action
Blades might be faulty. Enter the slotShow command to
determine status. For more information,
enter the diagDisablePost command;
then, use the slotPowerOff [slot
number] and slotPowerOn [slot
number[ command. Resolve the source
of the problem or replace the blade as
required.
Pins on the blade or the backplane might
be damaged.
Remove the blade from the chassis and
inspect the pins on the blade and on the
backplane inside the slot. Do not reinstall if
the pins on either component are damaged,
as this could damage pins on other
components. Replace the components as
required.
Component may not have power or may not
be firmly seated.
Ensure that the component is receiving
power (power LED should be on) and the
component is firmly seated.
Pins on the component or the backplane
might be damaged.
Remove the component from the chassis
and inspect the pins on the blade and
inside the chassis. Do not reinstall if the
pins on either component are damaged,
as this could damage pins on other
components. Replace parts as required.
An individual component is not operating
as expected.
The component might have failed. Enter the tempshow and sensorShow
command to determine the component
status. If the component is a CP blade or
port blade, enter the slotShow command
to determine the status. Replace the
component as necessary.