125
ELECTRICAL AND IGNITION
CONNECTOR SERVICING
6
Terminal Installation
Align terminal with connector housing and push
terminal with se al in to conn ector housing until
seated.
Packard
Connectors
IMPORTANT: Always use the appropriate meter
test probe s and ada pters when testing compo-
nents fitted with these terminals.
Disconnect
Lift latch(s). Remove connector.
Connect
Confirm the seal is in place. Push connector o nto
housing until latched.
Terminal Removal
A tab on the back sid e of the terminal engages a
shoulder in the connector housing to hold the ter-
minal in place. The terminal is removed by releas-
ing the tab and then pushing the terminal and wire
through connector housing.
Insert a thin tool into the connector above the ter-
minal to release tab.
Terminal Installation
Install wire gasket o n wires and fe ed wires
through the corr ect terminal position of the co n-
nector housing. Terminal is crimped onto wire and
then pulled back into connector housing until lock-
ing tab engages and terminal is seated.
Crimping Terminals
Strip insulation back 3/16 in. (5 mm). Position end
of wire strands in terminal past the wire crimp area
and the end o f insulation in the insula tion crimp
area of the terminal.
Capture all wire st rands in crimp ; leave no loose
strands. Crimp wire and insulation securely using
crimping pliers.
1. Latch
2. Terminal with seal
002456
dsc02124
1
2
1. Tab DRC5940a
002304
1