67
ENGINE MANAGEMENT MODULE (EMM)
DIAGNOSTIC SOFTWARE FUNCTIONS
4
Oil Control Settings
Set Oil Type
The TC-W3 oil type setting is the standard setting
for all outboards. Set TC-W3 for:
Operation with all TC-W 3 outboard o ils includ-
ing XD30, XD50, or XD100
Applications requiring maximum lubrication
Extreme app lications (racing or harsh cond i-
tions)
The XD100 setting provide s an op tion to ru n the
outboard at a reduced oil injection rate. This set-
ting REQUIRES th e use of Evinrude XD100 out-
board lub ricant and is not re commended for all
applications.
Use the XD100 setting for:
Conventional use (runabouts, cruisers)
Moderate applications
Powerhead Break-In
Use the diagnostic software to initiate break-in oil-
ing. Brea k-in is a predetermined oiling program
that runs fo r two hours of outb oard op eration,
above 2000 RPM.
1. Oil control setting 008571
A CAUTION
Running an Evinrude E-TEC outboa rd on
other grades of oil while set to the XD100
oil ratio will result in increas ed engine
wear and shortened outboard life.
1
1. Break-in oil setting 008108
1

Table of Contents