COPIER > FUNCTION > SPLMAN
Item Description
Display/adj/set range 0 to 1
0 : OFF
1 : ON
Default value 0
SPL89821
Title Shop demonstration mode
Details To display image data on color UI repeatedly to appeal
the product features to potential users.
Use case When appealing the product features to users at shops
Adj/set/operate method 1. Enter the setting value, and then press Apply key.
2. Turn OFF/ON the main power switch.
Display/adj/set range 0 to 1
Default value 0
Supplement/memo When the setting value is 1 at startup, the shop demonstration mode is enabled.
SPL71100 *
Title Setting of the duty of Off-hook PCB
Details This is the mode to make handsets of particular manufacturers to ring when fax reception mode is
set to "Fax / Tel (Auto Switch)".
Use case When fax reception mode is set to FAX/TEL switching
Adj/set/operate method 1. Enter the setting value, and then press Apply key.
2. Turn OFF/ON the main power switch.
Display/adj/set range 1 to 99
Default value 50
SPL00171
Title To change the maximum auto sleep shift time.
Details To change the maximum value of auto sleep shift time in Settings/Registration > Timer Settings >
Auto Sleep Time.
Use case When changing the setting time to shift to auto sleep mode
Adj/set/operate method 1. Enter the setting value, and then press Apply key.
2. Turn OFF/ON the main power switch.
Display/adj/set range From 0 (Default for Europe) to 60 min From 1 (Default for locations other than Europe) to Maximum
value for each model
Default value 1
SPL80100
Title Mask setting at copyboard scanning
Details To cancel the image mask occurs on the left edge at copyboard scanning.
Use case Upon request from user who does not satisfy with the mask on the left edge
Adj/set/operate method 1. Enter the setting value, and then press Apply key.
2. Turn OFF/ON the main power switch.
Display/adj/set range 0: Mask value according to the specifications of each job
1: No mask (0 mm)
Default value 0
SPL27354
Title PC-less update, RMDS environment setting
Adj/set/operate method 1. Enter the setting value, and then press Apply key.
2. Turn OFF/ON the main power switch.
Display/adj/set range 0: Production environment / Release environment
1: Production environment / Staging environment
2: Maintenance environment 1 / Release environment
3: Maintenance environment 1 / Staging environment
4: Maintenance environment 2 / Release environment
5: Maintenance environment 2 / Staging environment
Default value 0
SPL84194
Title ON / OFF of E-RDS function
8. Service Mode