Bit No. Function 1 0
Bit 1 - - -
Bit 2 - - -
Bit 3 - - -
Bit 4 - - -
Bit 5 - - -
Bit 6 - - -
Bit 7 Signal detection Detected Not detected
● Numeric value parameter
Parameter No. Function Setting range
01; - -
02; T1 timer 0 to 9999 (x 10 msec)
03; T2 timer 0 to 9999 (x 10 msec)
04; T3 timer 0 to 9999 (x 10 msec)
05; T4 timer 0 to 9999 (x 10 msec)
06; Signal detection table 0 to 16
07; Signal detection level 0 to 7
08; Number of signal frequency 0 to 9999
■ REORDER TONE
● Bit Switch
Bit No. Function 1 0
Bit 0 - - -
Bit 1 - - -
Bit 2 Signal frequency Changed Not changed
Bit 3 - - -
Bit 4 Judgment of intermittent signal start from valid ON signal start from either valid ON signal
or OFF signal
Bit 5 - - -
Bit 6 Signal form Continuous Intermittent
Bit 7 Signal detection Detected Not detected
● Numeric value parameter
Parameter No. Function Setting range
01; - -
02; T1 timer 0 to 9999 (x 10 msec)
03; T2 timer 0 to 9999 (x 10 msec)
04; T3 timer 0 to 9999 (x 10 msec)
05; T4 timer 0 to 9999 (x 10 msec)
06; Signal detection table 0 to 16
07; Signal detection level 0 to 7
08; Number of signal frequency 0 to 9999
■ MULTI
Not in use
8. Service Mode
306

Table of Contents

Related product manuals