Viewing Statistics
Configuring RMON History
ESW 500 Series Switches Administration Guide 400
17
Edit RMON History Page
The 
Edit RMON History Page
 contains the following fields:
• History Entry No. — Displays the entry number for the History Control Table 
page.
• Source Interface — Displays the interface (port or EtherChannel) from which 
the history samples are taken. The possible field values are: 
-
Port
 — Specifies the port from which the RMON information is taken.
-
EtherChannel
 — Specifies the EtherChannel from which the RMON 
information is taken.
• Owner — Displays the RMON station or user that requested the RMON 
information. The field range is 0-20 characters.
• Max No. of Samples to Keep — Indicates the number of samples to save.
• Sampling Interval — Indicates the time in seconds that samplings are taken 
from the ports. The field range is 1-3600. The default is 1800 seconds (equal to 
30 minutes).
STEP 3 Define the relevant fields.
STEP 4 Click Apply. The history control settings are modified, and the device is updated.
Viewing the RMON History Table
The 
RMON History Table Page
 contains interface specific statistical network 
samplings. Each table entry represents all counter values compiled during a single 
sample.