Chapter 11 Managing the SCMP
Configuring the SCMP
Options
The following options are available:
• 1st element — any one of the following:
–
Calling-Station-Id
–
NAS-Port-Id
–
User-Name
• 2nd element (optional) — any one of the following (if specified, usually not the option specified as
the first element):
–
Calling-Station-Id
–
NAS-Port-Id
–
User-Name
• 3rd element (optional) — any one of the following (if specified, usually the remaining option not
specified as either of the first two elements):
–
Calling-Station-Id
–
NAS-Port-Id
–
User-Name
Default = no elements concatenated with the GUID
Step 1 Disable the SCMP.
SCE(config)#no scmp
Step 2 Define the subscriber ID:
SCE(config)#scmp subscriber id append-to-guid radius-attributes Calling-Station-Id |
NAS-Port-Id | User-Name [Calling-Station-Id | NAS-Port-Id | User-Name] [Calling-Station-Id
| NAS-Port-Id | User-Name]
Step 3 Enable the SCMP.
SCE(config)#scmp
Configuring the RADIUS Client
You can configure the following options for the RADIUS client
• Define the parameters for retransmitting unacknowledged messages.
The RADIUS client polls the sockets to receive the next message and calls the SCMP engine to handle
it, based on the type of the received message. Messages that were not acknowledged can be retransmitted
up to the configured maximum number of retries.

Table of Contents

Other manuals for Cisco SCE8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SCE8000 and is the answer not in the manual?

Cisco SCE8000 Specifications

General IconGeneral
BrandCisco
ModelSCE8000
CategoryNetwork Hardware
LanguageEnglish

Related product manuals