Menu Menu Entry Options
LENS Load Lens Loads a lens into the system from internal memory.
Note: This feature is only available on the camin 3M.
Other camin need the cworld or cdisplay.
Unload Lens Unlaod the loaded lens. Conrm by pressing “yes”.
Invert Focus Inverts the selected scale, Conrm by pressing “yes”.
Invert Iris Inverts the selected scale, Conrm by pressing “yes”.
Invert Zoom Inverts the selected scale, Conrm by pressing “yes”.
Create Lens Allows you to create a lens le using the cvolution
hand unit (please refer to section 4.16.)
Delete Lens Allows you to delete a single lens le from the cvolu-
tion hand unit (please refer to section 4.18.6.)
Range nder AutoFocus Allows you to choose between o, M pre, M tog, M
pin, on
o: turns autofocus permanently o
M pre: “MARK press” activates autofocus as long as
the user button is being pressed (one of the user but-
tons needs to be assigned to MARK). After releasing
the user button, the focus will move to the preset knob
position.
M tog: “MARK toggle” activates autofocus by the
press of an user button and deactivates it by another
press (one of the user buttons needs to be assigned to
MARK). After deactivating the autofocus, the focus will
move to the preset knob position.
M pin: “MARK pin” allows to take a single reading from
the range nder. After releasing the user button the fo-
cus will STAY at this distance (one of the user buttons
needs to be assigned to MARK). If pressed permanant-
ly the autofocus is activated as long as the user button
is being pressed. Turning the knob over the xed focus
position assigns the control to the knob automatically.
on: turns autofocus permanently on
laser pointer activates the red reference/alignment laser of a cnder
III for 30 seconds
Warning: Always avoid direct eye contact with the
beam of the red alignment laser.