All content © 2017, cmotion GmbH. All specications subject to change without notice. http://www.cmotion.eu
53/112
4.6. Working with cforce
mini or plus motors
cforce and cforce mini motors can be connected to any cvolution camin 2M, 4M, 8M and 8M-
TC through the CBUS port using cable LCB-7. The cvolution camin 3M (and broadcast camin)
however are also equipped with an LBUS connector where all regular LCB cables can be used.
Up to 3 cforce and cforce mini motors can be connected in daisy-chain to any cvolution camin
and are identied in the hand unit menu by their serial number. Although all motor settings can
be changed through the cvolution hand unit, unlike passive motors, cforce save these settings
internally.
Note: The camin’s internal power booster has no eect on cforce
motors.
cforce motor Assignment
Press the SETUP button to assign the scale of the cforce mini motor to focus, iris or zoom.
Make sure that the assignment matches the lens scale the motor is engaged with.
■Press the SETUP button to indicate the current motor assignment. The F (Focus),
I (Iris) or Z (Zoom) indicator underneath the SETUP button will light up for three
seconds.
■Press the SETUP button repeatedly within 3 seconds to cycle through the motor
assignment options.
cforce motor Calibration
■Press and hold the SETUP button for three seconds to start calibration.
■Press the SETEUP button during calibration to interrupt the process.