6.2. Save/Load User Settings
With every cvolution system, it is possible to save up to 7 user proles. Each prole includes:
Motor Assignment, Direction, Torque, Ramp and Scale Sync/Scale Link. These individual
proles are saved internally when using the camin 3M but can be written to a USB when stick
when working with cvolution camin 2M, 4M, 8M and 8M-TC.
NOTE: Saving multiple Scale Sync proles is particularly useful when
regularly changing paired/synchronized lenses in a 3D production.
To save a user prole:
Press the “SELECT” button twice to enter the Menu.
Select “User Settings“.
Select “save“ and press “next“.
Select one of the slots, e.g. “User1“ and press “Select“.
Wait for “Data successfully written internally / written to USB” and press “exit”..
To save a pair of synchronized lenses to a user prole:
First synchronize the pair of lenses as described in section 6.1.3 on page 86.
Save your settings to a slot as described above.
Clear ALL synchronized scales from the “SYNC” menu.
Synchronize the second pair of lenses.
Save the settings to another slot.
To load settings:
Press the “SELECT” button twice to enter the Menu.
Select “User Settings“.
Select “load“ and press “next“.
Select one of the slots, e.g. “User1“ and press “Select“.
Wait for “Data successfully loaded / loaded from USB” and press “exit”.
NOTE: You cannot load empty settings.