All content © 2017, cmotion GmbH. All specications subject to change without notice. http://www.cmotion.eu
50/112
4.4.3. Calibration Menu
The calibration menu oers advanced calibration options.
■Press and release the CAL button to enter the CAL menu.
■Use the MENU SELECT WHEEL to select your option and press to execute.
■All, Lens and Rig calibrates all axes or all lens/rig axes respectively.
Quick Check is used to check scale calibration after a break in shooting. The camin checks one
end limit on all axis. If no valid value is returned, a full calibration of that axis is activated.
Manual calibration enables calibration of lenses with no mechanical scale stops, such as photo
style lenses. To manually calibrate these lenses follow these steps:
■Use the MENU SELECT WHEEL to select Manual and press Enter to select.
■Select the motor controlling the axis you want to calibrate.
■Use the MENU SELECT WHEEL to move the motor to the minimum value. The
WHEEL acts like a jog shuttle on a VCR. Turn clockwise to go forward and
increase speed, turn counter-clockwise to go backward or decrease speed. Press
“Set” when nished.
■Repeat the process for the maximum value.
■Check if calibration is correct by moving the axis controller all the way to both
limits.