Repeat this process to congure all other connected motors to meet your setup
needs.
Note: The default motor assignment on the camin 8M and 8M-TC is as
follows:
M1 / M3 = Focus
M2 / M4 = Iris
M5 / M6 = Zoom
M7 = Interaxial
M8 = Convergence
Depending on your setup, the focus puller’s hand unit should now be congured with two focus
motors controlled by the knob, two iris motors controlled by the slider and two zoom motors
controlled by the zoom unit. The Stereograher’s hand unit can be congured to control IA and
Convergence, PLUS “Mirror, Tilt and Rotation” when using 8 passive motor PLUS 3 active
motors connected through the CBUS port.
Note: If you want to assign more than two motors to a single scale (e.g.
Panoramic/Virtual Reality setups), simply assign the corresponding
motors to the required scale.