D-4 Compaq ProLiant ML370 Setup and Installation Guide
Compaq Confidential – Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant ML370 Setup and Installation Guide Comments:
Part Number: 120137-002 File Name: l-appd Specifications and Connector Interfaces Last Saved On: 12/10/99 12:24 PM
Rack and Tower Models with Optional Redundant
Power Supply
Table D-3
Operating and Performance Specifications
for Tower and Rack Models with Redundant Power Supply
Dimensions
Height (without feet) 17.92 inch 45.52 cm
Depth 22.67 inch 57.58 cm
Width 8.83 inch 22.43 cm
Weight
No drives installed 50.0 lb 22.68 kg
Input Requirements
Rated input voltage 100 to 240 VAC
Rated input frequency 50 - 60 Hz
Rated input current 8A (110 V) – 4A (220 V)
Rated input power 728 W
BTUs per hour 2490
Power Supply Output
Power
Rated steady-state
power
400 W
Maximum peak power 445 W
Temperature Range
Operating 50° to 95°F10° to 35°C
Shipping -22° to 122°F-30° to 50°C
Relative Humidity
(noncondensing)
Operating 8% to 90% 8% to 90%
Non-operating 5% to 95% 5% to 95%
Wet Bulb Temperature
Maximum 101.7°F 38.7°C