Engineering Manual Introduction
9
Network 1
Network 2
1000
CONTROL
PANEL
5 Outputs
8 Zones
Network 1 (Supports only remote keypads) and LEC2s
Network Wiring = 6 Core
Max 4
Engineer’s keypad
(cannot have zones
or outputs)
8 Outputs
30 ID Zones
Network2-Wiring Option 3
MIDNodes or IDNodes
Network Wiring = 4 Core
MIDNode or IDNode
Network2-Wiring Option 2
Remote Keypads/LEC2s
100m max to
furthest
keypad/LEC2
1 Output
2 Zones
1 Output
2 Zones
1 Output
2 Zones
1 Output
2 Zones
Network2-Wiring Option 1
XNodes and/or MNodes
100m max
100m max to
furthest keypad
Network Wiring = 4 Core
2 Outputs
8 Zones 8 Zones
Max 16
8 Zones
Max 4
2 Outputs 2 Outputs
100m max
Network Wiring = 6 Core
Max 5
100m max to
furthest
keypad/LEC2
1 Output
2 Zones
1 Output
2 Zones
1 Output
2 Zones
1 Output
2 Zones
1 Output
2 Zones
An XNode/MNode is
able to drive 4 Remote
Keypads and a
Loudspeaker
XNode/
MNode
1
XNode/
MNode
2
XNode/
MNode
3
300m max
to furthest
XNode/
MNode
NOTE:
Do not connect an
XNode/MNode to the
same network as an ID
Node or keypad
Maximum of 120 zones
with four MIDNodes.
Maximum of 40 zones
with two IDNodes.
Figure 3. Network Architectures for the M1000 Control Panel