Engineering Manual Engineer Menu 2-8
119
#,## NODE FUSE Network #, device No. ## is a Node that has a tripped fuse
#,## NODE LOST Network #, device No. ## is a Node that has been removed
#,## NODE TAMPER Network #, device No. ## is a Node that has a tamper condition
#,## PSU FUSE Network #, device No. ## MSPSU keypad or Network fuse active
#,## REM ADDED Network #, device No. ## is a remote keypad that has been added to the system
#,## REM LOST Network #, device No. ## is a remote keypad that has been removed
#,## REM TAMPER Network #, device No. ## is a remote keypad that has a tamper condition
#,## XNODE ADDED Network #, device No. ## is a XNode/MNode that has been added to the system
#,## XNODE FUSE XNode/MNode fuse failed
#,## XNODE LOST Network #, device No. ## is a XNode/MNode that has been removed
#,## XNODE TAMP XNode/MNode lid tamper
24 Hr WARDS:- 24 Hour Alarm on wards
24H RESTORE ####- 24 Hour Alarm on zone #### reset
24Hr ALARM #### 24 Hour alarm from zone number ####
24HR OMIT:- 24 Hour group omitted in wards
24HR REINST:- 24 Hour group reinstated in wards
ABORT ON WARDS:- Alarm aborted on wards
ACCESS ## Passcode entered for user number ##
ACCESS ### Passcode entered for user number ###
ACCESS #### Passcode entered for user number ####
ACCESS FAILED Access failed due to code lock in operation
ACCESS ZONE #### Entry zone #### activated
ALARM #### Alarm from zone number ####
ALARM WARDS: Alarm in wards
ATE L.F. ALL All networks from a communicator to an ARC are unavailable
ATE L.F. RESTORE The network connection from a communicator to an ARC has been restored
ATE L.F. SINGLE A network connection from a dual-path communicator to an ARC is unavailable
AUTOSET # OFF Autoset timer off
AUTOSET # ON Autoset timer on
AUX RESTORE #### Technical alarm from zone number #### reset
BELL TAMPER bell tamper
AUXILIARY #### Technical alarm from zone number ####
AUXILIARY # TAMP Not used
AUXILIARY FUSE Auxiliary Fuse failed
BATTERY FAULT Not used
BATTERY LOAD TST Battery load test carried out
BATTERY LOW Battery voltage is low
BATTERY MISSING Battery is not connected
BATTERY RESTORE Battery restored to healthy condition
BEAM PAIR #### First activation of a beam pair zone number ####
BELL BOX TAMPER Not used
BELL FUSE Bell fuse tripped
BELL TAMP OMIT Bell tamper omitted after confirmation timer has expired
BELL TESTED:- Bell tested for wards
BELLS ACTIVE:- Bell active for wards
CHANGE CODE ## User code for user ## changed
CHANGE CODE ### User code for user ### changed
CHANGE TAG ## User tag changed for user ##
CHANGE TAG ### User tag changed for user ###
CHNG CODE #### User code changed for user ####
CHNG TAG #### User tag changed for user ####
CNFG CHANGE ### Configuration change for user ###
CNFG CHANGE #### Configuration change for user ####
CODE ## Passcode entered for user number ##
CODE ### Passcode entered for user number ###
CODE #### Passcode entered for user number ####
CODE LOCK # OFF Code lock number # is off
CODE LOCK # ON Code lock number # is on