Engineer Menu 2-8 Engineering Manual
120
CODE LOCKED ## User number ## attempted to use their passcode whilst locked-out
CODE LOCKED ### User number ### attempted to use their passcode whilst locked-out
CODE LOCKED #### User number #### attempted to use their passcode whilst locked-out
CODE TAMPER Keypad locked out for 5 minutes due to invalid entry of passcode
COMMS FAILED On-board modem failed to communicate with ARC
COMMS TEST CALL Communications test call started
CONFIG CHANGE ## Configuration change for user ##
DATE CHANGED AT System date changed at
DATE CHANGED TO System date changed to
DEFAULT USER User 01 (manager) code defaulted
DEFAULT USER ## Not used
DEFAULT USER ### Not used
DEFAULT USER #### Not used
DEFERRED SET:- Deferred set on wards
DL DISCONNECT FL) Downloader disconnected incorrectly
DL DISCONNECT OK Downloader disconnected
DURESS CODE ## Duress alarm from user number ##
DURESS CODE ### Duress alarm from user number ###
DURESS CODE #### Duress alarm from user number ####
ENG HW DEFAULTED Panel factory reset
ENGINEER ARRIVES Engineer is logged on the system
ENGINEER DEPARTS Engineer is logged off the system
ENTRY TIME-OUT:- Entry mode timed out for wards
ENTRY ZONE #### Entry mode started from zone number ####
EXIT CANCELLED:- Exit mode cancelled for wards
EXIT STARTED:- Exit mode started for wards
EXT LINE FAULT Not used
EXT LINE RESTORE Not used
FACTORY RESTART Factory default loaded
FIRE ALARM #### Fire alarm from zone number ####
FIRE RESET:- Fire Alarm reset
FIRE WARDS:- Fire alarm on wards
FIRST KNOCK #### First activation of zone number #### (zone with Double-Knock attribute)
FROM REMOTE #,## Not used
HI-SECURITY SET: Wards set using “High Security” feature
ID LOOP RESTORED Short circuit cleared from ID loop
ID LOOP SHORTED ID loop is short-circuited
KEYPAD PANIC ### Panic alarm raised from keypad (buttons 1 and 3 pressed)
KEYSWITCH ### Keyswitch zone #### activated
LOCAL ON LINE Local connection with Downloader
LOCAL SERV CALL Local connection with Downloader
LOCAL SERV END Not used
LOCKSET #### ON Lock set zone #### activated
LOCKSET #### OFF Lock set zone #### deactivated
LOCKSET WARD ON Lockset for ward enabled
MAIN POWER ON Mains power applied to control panel
MAINS POWER OFF Mains power removed from control panel
MASK FLT S #### Zone #### masked when set
MASK FLT U #### Zone #### masked when unset
MASK TMP S #### Masking zone #### masked when set
MASK TMP U #### Masking zone #### masked when unset
MENU TIMEOUT ## System timed out user ##, and returned to the normal standby screen
MENU TIMEOUT ### System timed out user ###, and returned to the normal standby screen
MENU TIMEOUT #### System timed out user ####, and returned to the normal standby screen
MODEM LOCKOUT Modem locked-out (4 failed attempts made via Lineload)
NETWORK # FUSE Network # polyfuse tripped
NODE TAMP OMIT MNode/XNode tamper omitted after confirmation timer expired
NORM. REST. #### Normal alarm restore