Engineer Menu 1-3 Engineering Manual
38
restarts each time a detector is triggered in the Secure ward. When the timer expires, the
system attempts to set the ward automatically.
11 – Bell & Strobe
This option allows you to select which wards will trigger the external sounder (bell) and
strobe outputs on the control panel. Refer to the Bell Delay and Bell Duration notes on
page 57.
12 – Foyer Mode
This enables ward 1 to:
Set automatically when all wards selected in the Foyer Mode attribute have been
set. For example if wards 2, 3 and 4 are selected, the system will automatically set
ward 1 when the last of these wards is set.
Unset automatically when any one of the selected wards has been unset (with all
the wards being previously set).
Ward 1 is intended to be a foyer area, which needs to set or unset automatically.
To prevent the foyer setting before that of the last ward selected for setting, you
should ensure that the exit time of ward 1 (page 57) is greater than that of the
other wards.
Do not select ward 1 in the Foyer Mode option.
Ward 1 can be configured to set instantly; see page 77.
13 – Unset Fire
This attribute determines whether outputs that follow a Fire Alarm event (page 43 or 52)
activate only when a Fire zone (page 27) is set, or when the zone is either set or unset.
If a ward has this attribute, a fire alarm from the ward will activate the outputs if the ward
is set or unset. If a ward does not have this attribute, a fire alarm from the ward will
activate the outputs only when the ward is set.
14 – Multiply Ack
This option allows you to designate which wards will use the Double Knock counter (page
61).