033 – Tamper Alarm
Activates when any type of tamper condition is triggered; deactivates when all tamper
conditions have been reset. This output acts as a "global" tamper indication for any type
of tamper.
034 – Rem Service Call
Activates when the system is online with a remote PC and the Downloader software.
035 – Code Accepted
Activates after any valid user code has been entered. The output deactivates one
second later if the output is latched, or for the length of the pulse if the output is pulsed.
036 – Service Required
Activates when the Service Time (page 60) has expired; deactivates when the engineer
code is entered.
037 – Reset Required
Activates when the system requires an engineer or remote reset; deactivates when the
system is reset either by the engineer or by a remote reset.
038 – Strobe On Set
Activates when there is an alarm, and deactivates when the alarm is reset by the user.
This output is also active for 10 seconds after a user sets the system.
039 – Duress Alarm
Activates when a duress code is entered (as set up in User option 2-4); deactivates when
the duress alarm is reset.
040 – System Part Set
Activates when not all wards are set; deactivates when all wards are set or unset.
041 – LockSet Unlocked
Active when a Lock Set zone (page 28) is unlocked; deactivates when all Lock Set zones
on the system are locked.
042 – Set Failed
Activates when any ward fails to set (e.g. because a zone is active); deactivates when
the set fail condition is reset.
043 – Shunt Code
If the output is latched, the output activates for 2 seconds when a shunt code (as set up
in User option 2-4) is entered. If the output is pulsed, it activates for the duration of the
pulse.
044 – Random Output On
Activates randomly (between 5 and 60 minutes).
045 – Modem Lockout
Activates when the modem is locked-out (four failed attempts); deactivates when a
Manager user code is entered or after 4 hours. This is not applicable to the M550 and
M750.
046 – Bell Tamper
Activates when the bell tamper is triggered; deactivates when the alarm is reset.