Example
If the value 4500 is received from ID 2291, the value 42 from ID 2303, and the value 0 from ID 2305, the result is 45.00 kWh.
12.4.6 Energy Trip Counter
The energy trip counter counts the quantity of energy that the drive gets from the supply network. The counter is in the submenu
Trip counters. It is possible to reset the counter with the PC, the control panel, or the fieldbus. To read the value of the counter
through fieldbus, use these ID numbers.
The value has always 4 digits. The format and the unit of the counter change to agree with the energy trip counter value. See the
following example. It is possible to monitor the energy counter format and unit with ID 2307 Energy Trip Counter Format and ID
2309 Energy trip Counter unit.
Example
0.001 kWh
0.010 kWh
0.100 kWh
1.000 kWh
10.00 kWh
100.0 kWh
1.000 MWh
10.00 MWh
100.0 MWh
1.000 GWh
and so on
Energy Trip Counter Format
The energy trip counter format gives the position of the decimal point in the value of the Energy Trip Counter.
40 = 4 digits, 0 fractional digits
41 = 4 digits, 1 fractional digit
42 = 4 digits, 2 fractional digits
43 = 4 digits, 3 fractional digits
Example
0.001 kWh (Format = 43)
100.0 kWh (Format = 41)
10.00 MWh (Format = 42)
The energy trip counter unit gives the unit for the value of the Energy Trip Counter.
0 = kWh
1 = MWh
2 = GWh
AB298035655957en-000201 / DPD01083324 | Danfoss A/S © 2023.08
Fault Tracing
VACON® 100 FLOW
Application Guide