FC 202 N355 N400 N450
Continuous kVA (at 400 V) [kVA] 416 456 456 516 482 554
Continuous kVA (at 460 V) [kVA] 430 470 470 540 540 582
Continuous kVA (at 480 V) [kVA] 468 511 511 587 587 632
Maximum input current
Continuous (at 400 V) [A] 578 634 634 718 670 771
Continuous (at 460/480 V) [A] 520 569 569 653 653 704
Maximum number and size of cables per phase
- Mains [mm
2
(AWG)]
4x120 (4x250 mcm) 4x120 (4x250 mcm) 4x120 (4x250 mcm)
- Mains with disconnect [mm
2
(AWG)]
4x120 (4x250 mcm) 4x120 (4x250 mcm) 4x120 (4x250 mcm)
- Mains with fusible disconnect [mm
2
(AWG)]
4x120 (4x250 mcm) 4x120 (4x250 mcm) 4x120 (4x250 mcm)
- Mains with contactor [mm
2
(AWG)]
4x120 (4x250 mcm) 4x120 (4x250 mcm) 4x120 (4x250 mcm)
- Motor [mm
2
(AWG)]
4x120 (4x250 mcm) 4x120 (4x250 mcm) 4x120 (4x250 mcm)
Drive module power loss at 400 V [W]
(1) (2) (3)
6178 6928 6851 8036 7297 8783
Drive module power loss at 460 V [W]
(1) (2) (3)
5322 5910 5846 6933 7240 7969
Drive efficiency
(2)
0.98 0.98 0.98
Output frequency [Hz]
(4)
0–590 0–590 0–590
Heat sink overtemperature trip [°C (°F)] 110 (230) 110 (230) 110 (230)
Control card overtemperature trip [°C (°F)] 80 (176) 80 (176) 80 (176)
PHF overtemperature trip [°C (°F)] 150 (302) 150 (302) 150 (302)
dU/dt filter overtemperature trip [°C (°F)] 150 (302) 150 (302) 150 (302)
Sine-wave filter overtemperature trip [°C (°F)] 150 (302) 150 (302) 150 (302)
1
Typical power loss is at normal conditions and expected to be within ±15% (tolerance relates to variety in voltage and cable conditions.) These values are based on a typical motor
efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the drive. Applies to dimensioning of drive cooling. If the switching frequency is higher than the default
setting, the power losses can increase. LCP and typical control card power consumptions are included. For power loss data according to EN 50598-2, refer to drives.danfoss.com/
knowledge-center/energy-efficiency-directive/#/. Options and customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for slots A and B
each add only 4 W.
2
Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency. Efficiency measured at nominal current. For energy efficiency class, see the Ambient Conditions
section. For part load losses, see drives.danfoss.com/knowledge-center/energy-efficiency-directive/#/.
3
See also Input Power Option Losses.
4
If using an output filter, the output frequency is limited further. See the Motor Output (U, V, W) section.
Table 81: Electrical Data, Mains Supply 3x380–480 V AC
FC 202 N500 N560
High/normal overload
High overload=150% or 160% torque for a duration of 60 s. Normal overload=110%
torque for a duration of 60 s.
HO NO HO NO
Typical shaft output at 400 V [kW] 450 500 500 560
Specifications
Operating Guide | VLT® AQUA Drive FC 202
AQ262141056213en-000101 / 130R0882 | 163
Danfoss A/S © 2018.10

Table of Contents

Other manuals for Danfoss VLT AQUA Drive FC 202

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AQUA Drive FC 202 and is the answer not in the manual?

Danfoss VLT AQUA Drive FC 202 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AQUA Drive FC 202
CategoryDC Drives
LanguageEnglish

Related product manuals