Symbologies
332 Gryphon™ I GD4100/GM4100
GS1 DataBar™ Expanded Set Length 1
This feature specifies one of the barcode lengths for GS1 DataBar™ Expanded Length Control.
Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in
Fixed Length Mode. Length includes the barcode’s data characters only.
The length can be set from 1 to 74 characters.
Follow these instructions to set this feature:
1. Determine the desired character length (from
1 to 74). P
ad the number with leading
zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode
.
3. Scan the barcode: SELECT GS1 DataBar™ EXPANDED LENGTH 1 SETTING.
4. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent
the length setting which was determined in the steps ab
ove. You will hear a two-beep indi-
cation after the last character
NOTE
.
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mo
de
.
This completes the procedure. See Table 39 for some examples of how to set this feature.
Table 39. GS1 DataBar™ Expanded Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
01 Character 07 Characters 52 Characters 74 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT GS1 DataBar™ EXPANDED LENGTH 1SETTING
4
Scan Two Characters From
Appendix E, Keypad
‘0’ and ‘1’ ‘0’ and ‘7’ ‘5’ and ‘2’ ‘7’ AND ‘4’
5 Scan ENTER/EXIT PROGRAMMING MODE
If you make a mistake before the last character, scan the CANCEL
barcode to abort and not save the entry string. You can then start
again at the beginning.