LED and Beeper Indications
388 Gryphon™ I GD4100/GM4100
Table 50
Programming Mode - The following indications ONLY occur when the reader is in Programming Mode.
Label Program-
ming Mode
Entry
A va
lid programming label has
been sc
anned.
LED blinks continuously Reader sounds four low fr
eq
uency beeps.
Label Program-
ming Mode
Reject
ion of
Label
A label has been rejected. N/A
Reader sounds three times at
lowe
st frequency & current vol-
ume.
Label Program-
ming Mode
A
ccep
tance of
Partial Label
In cases where multiple labels
must be
scanned to program
one feature, this indication
acknowledges each portion as
it is successfully scanned.
N/A
Reader sounds one short beep at highest
fr
equen
cy & current volume.
Label Program-
ming Mode
Accep
tance of
Programming
Configuration option(s) have
been successfully pr
ogra
mmed
via labels and the reader has
exited Programming Mode.
N/A
Reader sounds one high fre-
quency beep and 4 low fre-
quency beeps followed by
re
se
t beeps.
Label Program-
ming Mode Can-
cel Item Entry
Cancel label has been scanned. N/A
Reader sounds two times at
low fr
equency and current vol-
ume.
. Programming Mode Indications
Error Codes
Upon startup, if the reader sounds a long tone, this means the reader has not passed its
automatic Selftest and has entered FRU (Field Replaceable Unit) isolation mode. If the reader is
reset, the sequence will be repeated. The following table describes the LED flashes/beep codes
associated with an error found.
NUMBER OF LED
FLASHES/BEEPS
ERROR CORRECTIVE ACTION
1 Configuration
Contact Helpdesk for assistance
2Interface PCB
4 Reader Module
5 Laser Pointer (if so equipped)
6Digital PCB
14 CPLD/Code Mismatch