Industrial 2 of 5
Product Reference Guide 279
Industrial 2 of 5 Set Length 1 — cont.
Industrial 2 of 5 Set Length 2
This feature specifies one of the barcode lengths for Industrial 2 of 5 Length Control. Length 2
is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed
Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The
length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 0 s
pecifies to ignore this length (only
one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 1 to 50 —
or 0
to ignore this length). Pad
the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20,
etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mo
d
e.
3. Scan the barcode: SELECT INDUSTRIAL 2 OF 5 LENGTH 2 SETTING.
ENTER/EXIT PROGRAMMING MODE
Select Industrial 2 of 5 Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not
save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT
01 = Length 1 is 1 Character