Symbologies Enter/Exit Programming Mode
Product Reference Guide
225
Code 93 Set Length 1
This feature specifies one of the bar code lengths for Code 93 Length Control
on page 224. Length 1 is the minimum label length if in Variable Length on
page 224 Mode, or the first fixed length if in Fixed Length on page 224 Mode.
Length includes the bar code’s data characters only.
The length can be set from 01 to 50 characters. See "Set Length 1" on
page 306
for more detailed programming instructions.
Select Code 93 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
$CC9L1
~
DEFAULT
01 = Length 1 is 1 Character