EasyManuals Logo
Home>Datalogic>Barcode Reader>QuickScan I QD21 1 Series

Datalogic QuickScan I QD21 1 Series User Manual

Datalogic QuickScan I QD21 1 Series
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #98 background imageLoading...
Page #98 background image
Enter/Exit Programming Mode Green Spot Duration
88 QuickScan™ I QD21X1 / QM21X1 / QBT21X1
Flash Off Time
This feature specifies the OFF time for the indicator LED while in Flash Mode.
The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100
millisecond increments. See "Flash Off Time" on
page 304 for more detailed
programming instructions.
Select Flash OFF Time Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
Green Spot Duration
Specifies the duration of the good read pointer beam after a good read.
Green Spot Duration = Disable (Green Spot is Off)
Green Spot Duration = Short (300 msec)
Green Spot Duration = Medium (500 msec)
Green Spot Duration = Long
(800 msec)
$CSNFF
~
DEFAULT
06 = Flash is OFF for 600ms
$CLSSP00
$CLSSP01
$CLSSP02
$CLSSP03
DEFAULT

Table of Contents