Enter/Exit Programming Mode LED and Beeper Indicators
82 QuickScan™ I QD21X1 / QM21X1 / QBT21X1
Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on
following a good read. The good read LED on time can be set within a range of
0.1 to 25.5 seconds in 100ms increments. A setting of 00 keeps the LED on
until the next trigger pull. See "Good Read LED Duration" on page 300 for more
detailed programming instructions.
Select Good Read LED Duration Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
$CLAGL
~
DEFAULT
003 = Good Read LED stays on for
0.3 seconds.
NOTE
Indicators are dimmed during sleep.