EasyManua.ls Logo

Datalogic QuickScan I QD21 1 Series - BC412 Set Length 2

Datalogic QuickScan I QD21 1 Series
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Symbologies Enter/Exit Programming Mode
Product Reference Guide
245
BC412 Set Length 2
This feature specifies one of the bar code lengths for BC412 Length Control on
page 243. Length 2 is the maximum label length if in Variable Length on page
243 Mode, or the second fixed length if in Fixed Length on page 243 Mode.
Length includes the bar code’s check, data, an
d full-ASCII shift characters. The
length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 00 specifies to
ig
nore this length (only one fixed length). See "Set Length 2" on
page 307 for
more detailed progr
amming instructions.
Select Code 39Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
$CBCL2
~
DEFAULT
50 = Length 2 is 50 Characters

Table of Contents

Related product manuals