Delta VP3000 Series - 5-3-2 IM Autotune; 5-3-2-1 Adjustment Flowchart

Delta VP3000 Series
714 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 Initial Operation and Adjustment | VP3000
216
5-3-2 IM Autotune
5-3-2-1 Adjustment Flowchart
A-0
IM
Motor Type C0-00
0: IM
Motor Parameters
d1-01 IM1 Rated Power
d1-02 IM1 Rated Current
d1-03 IM1 Rated Voltage
d1-04 IM1Rated Speed
d1-05 IM1 Rated FREQ
d1-06 IM1 Pole Number
IM1 Autotune d1-00
2: IM simple active autotune
Autotune Success
Autotune error
Measured resistance, inductance
or Lm value error
A-3
IMFOC
A-1
IMVF
A-2
IMSVC
If the motor executes
active autotune
IM1 Autotune d1-00
3: IM advanced active autotune
Is the OPER FREQ higher
than motor rated FREQ
IM1 Autotune d1-00
1: IM static autotune
YES
YES
NO
NO
YES
NO
Check motor parameters
d1-08 IM1 Rs
d1-09 IM1 Rr
d1-10 IM1 Lm
d1-11 IM1 Lx

Table of Contents