9-1 Maintenance and Inspections
Stop the drive operation, turn off the power and remove the cover before the maintenance. Even if the
power has been turned off, a charge may still remain in the filter capacitors with hazardous voltages
which takes a certain time to discharge. To avoid danger, strictly follow the waiting time mentioned in the
precautions after the drive is powered off before performing the inspection.
Ambient Environment
Check Item
Methods and Criterion
Maintenance Period
Daily
Half
Year
One
Year
Check the ambient temperature, humidity,
vibration and if there is any dust, gas, oil or water
drops.
Visual inspection and
measurement with equipment
with standard specifications
Check for any dangerous objects in the
surroundings
Visual inspection
Voltage
Check Item
Methods and Criterion
Maintenance Period
Daily
Half
Year
One
Year
If the voltage of the main circuit and control
circuit are correct
Measure with multi-meter with
standard specifications
Digital Keypad Display
Check Item
Methods and Criterion
Maintenance Period
Daily
Half
Year
One
Year
If the display is clear for reading
Visual inspection
If there is any missing characters on the display
Visual inspection
Mechanical Parts
Check Item
Methods and Criterion
Maintenance Period
Daily
Half
Year
One
Year
Check for any abnormal sounds or vibrations
Visual and auditory inspection
Check for any loose screws
Tighten the screws
Check for deformed or damaged parts
Visual inspection
Check for any color changed due to overheating
Visual inspection
Check for any dust or dirt
Visual inspection

Table of Contents