Chapter 8 TroubleshootingVP3000
444
ID No.
Warning Name
Descriptions
76
ExCom inner error
(ECiF)
Serious internal error
Action and Reset
Action Condition
Internal memory saving error
Action Time
Immediately act
Warning Setting Parameter
N/A
Reset Method
Cycle the power
Reset Condition
No
Record
No
Cause
Corrective Actions
Noise interference
Verify the wiring of the control circuit and wiring/grounding of the main circuit to
prevent interference.
Cycle the power
The memory is broken
Reset to the default value and check if the error still exists. If yes, replace the
communication card.