Chapter 8 TroubleshootingVP3000
448
ID No.
Warning Name
Descriptions
80
Ethernet link fail
(ECEF)
Ethernet cable is not connected
Action and Reset
Action Condition
Hardware detection
Action Time
Immediately act
Warning Setting Parameter
N/A
Reset Method
Manual reset
Reset Condition
No
Record
No
Cause
Corrective Actions
The cable is loose
Re-connect the network cable.
Bad quality of the cable
Replace the cable