Chapter 11 Specification | VP3000
698
Altitude Derating Curve
Condition
Operating Environment
High Altitude
If the AC motor drive is installed at an altitude 0–1000 m, follow normal operation
restriction. For altitudes of 1000–2000 m, decrease 1% of the drive rated current or
lower 0.5°C of temperature for every 100 m increase in altitude. The maximum altitude
for Corner Grounded is 2,000 m. If installing at an altitude higher than 2000 m is
required, contact Delta for more information.
Table 9-8
Figure 9-2
The rated output current derating (%) for different altitudes above sea level:
Altitude above Sea Level
(meter)
0
1000
1500
2000
Output Current / Rated
Current (%)
100
100
95
90
Table 9-9
80
85
90
95
100
105
0 500 1000 1500 2000
Drive's Rated Output
Current (%)
Altitude above Sea Level (Meter)
Derating for High Altitude