IMPORTANT
The values "torque_red“ and "angle_red“ are only available if the connected
MINIMAT–EC-Servo screwdriver is equipped with a second measuring
system.
IMPORTANT
Statistical values can only be printed if the command "Statistics" is
inserted ahead of the print command in the screwdriving process.
At the time of delivery the standard format is:
@date_iso @time PG: @prog ST: @step TQ: @torque AN: @angle @errortext
Issue:
2013-04-24 07:13:37 PG: 12 ST: 3 TQ: 2.15 Nm AN: 1080
°OK
The amended format string
@date_euro @time Program: @prog step: @step fault: @error runtime:@runtime torque:
@torque angle: @angle
delivers following output, e.g.:
24.01.2013 07:13:37 Program: Step 12: 3 faults 0 runtime: 0.5 s torque: 2.15 Nm angle:
1080
°