3-20
Overview, continued
Dashboard
display
(continued)
NOTE: Where applicable, the values reported within a parameter in the dashboard
refer to measurements on channels A, B, C, and D respectively. The measurement
values for each channel are updated approximately once per second while monitoring is
on. Display size can also be adjusted with 2x3 (small), 3x4 (medium) or 4x6 (large)
matrix, depending on user application.
Compliance: The dashboard is color coded such that green indicates the parameter is
within limits and/or no events have occurred since the last time the panel was cleared.
Red indicates the parameter is extremely out of limits and/or events of that type have
occurred since the panel was last cleared.
Dashboard
function keys
Function keys are available to view preset parameters, change the display size, or
change parameters and channels displayed in the dashboard.
Presets provide a set of default parameters that will be displayed in the dashboard. Use
the corresponding functions keys for the three different presets available:
Power Quality - uses the standard power quality parameters based on IEEE 1159 PQ
standard. The dashboard displays standard Power Quality preset parameters by default.
The default parameters for PQ as displayed in the 3x4 (medium) panel are (from first
row left to right): Vrms, Irms, Freq, Vthd, Pst, Sag, Swell, Transient, Active Power,
Vithd, V neg/pos unbalance, I neg/pos unbalance.
Energy/Demand - default parameters for Energy/Demand as displayed in the 3x4
(medium) panel are (from first row left to right): Energy, Demand, Predicted Demand,
Vrms, Irms, W, VA, VAR, PF, Daily Peak Dmd, Weekly Peak Dmd, Monthly Peak
Dmd.
HDPQ-318
Shop for Power Metering products online at:
1.877.766.5412
www.PowerMeterStore.com