Section 5847 User Instructions
Issue AL, July 24, 2006 Spec. Nos. 586505000 and 5865055000 (Model LMS1000)
Page 2-26 Chapter 2. Operating LMS1000
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
47) System manual equalize/test time set
48) System temperature compensation slope set
49) System maximum temperature compensation voltage set
50) System minimum temperature compensation voltage set
51) System high temperature alarm #1 set
52) System high temperature alarm #2 set
53) System low temperature alarm #1 set
54) System low temperature alarm #2 set
55) System relay test time set
56) System equalize multiplier set
57) Temperature displayed in degrees Celsius
58) Temperature displayed in degrees Fahrenheit
59) Manual equalize/test started
60) Manual equalize/test stopped
61) System relay test started
62) System relay test stopped
63) LPS MCA password set
64) MCA MSG set
65) Router bb MSG set
66) PCU bb-cc MSG set
67) Dist panel bb-cc MSG set
68) Relay bb-ss MSG set
69) PCU bb-cc set ON
70) PCU bb-cc set OFF
71) Dist bb-cc shunt dd added
72) Dist bb-cc shunt dd removed
73) Dist bb-cc shunt dd changed
74) LPS nnnA PCU bb-cc new capacity
75) Equalize/test mode is active
76) Float mode is active
77) LPS I/O Bd bb-ss added
78) LPS I/O Bd bb-ss deleted
79) LPS I/O Bd bb-ss moved
80) LPS I/O Bd bb-ss replaced
81) I/O Bd bb-ss custom message set
82) I/O Bd bb-ss input scale set
83) I/O Bd bb-ss output scale set
84) I/O Bd bb-ss load type set
85) I/O Bd bb-ss binary input dd alarm orientation changed
86) LPS MCA auxiliary load deactivated
87) LPS MCA auxiliary load activate
Each entry in the Event Log contains the following items:
1) Name and number of user responsible for the event.
2) Description of the event.
3) Date and time of the event.
Command EVENTS and CLR EVENTS: The event log can be viewed or cleared by
using the commands EVENTS or CLR EVENTS, respectively. These commands are
available to users programmed for access to level 6 commands.