You can skip positions and you can repeat process variables.
Table 7-1: Default configuration for display variables
Display variable Process variable assignment
Display Variable 1 Mass flow rate
Display Variable 2 Mass total
Display Variable 3 Volume flow rate
Display Variable 4 Volume total
Display Variable 5 Density
Display Variable 6 Temperature
Display Variable 7 Drive gain
Display Variable 8 None
Display Variable 9 None
Display Variable 10 None
Display Variable 11 None
Display Variable 12 None
Display Variable 13 None
Display Variable 14 None
Display Variable 15 None
Configure a two-line display screen
Display
Menu > Configuration > Display Settings > Display Variables > 2-Value View
ProLink III Device Tools > Configuration > Transmitter Display > Display Variables > 2 PV Screen Slot #X
Field Communicator Configure > Manual Setup > Display > Display Variables > Display: Two-Variable View
You can configure one display screen to show two process variables at a time. For each of these process
variables, the current value and the measurement is shown.
The two-line display screen operates like one of the basic 15 screens. You can use ⌄ and ⌃ to scroll to it. If Auto
Scroll is enabled, the two-line screen will be the last screen in the cycle.
7.1.3 Configure the number of decimal places (precision) shown on
the display
Display
Menu > Configuration > Display Settings > Decimals on Display
ProLink III Device Tools > Configuration > Transmitter Display > Display Variables > Decimal Places for x
Field Communicator Configure > Manual Setup > Display > Decimal Places
Configure device options and preferences Configuration and Use Manual
March 2019 MMI-20025166
120 Micro Motion Model 5700 Transmitters with Configurable Outputs