Table 7-11: Output Fixed conditions (continued)
Name Ignorable
[122] Discrete Output 3 Fixed No
Frequency Output 2 Fixed No
mA Output 3 Fixed No
Output Saturated
Default severity: Out of Speculation
Severity configurable: Yes
Fault Timeout applicable: No
Table 7-12: Output Saturated conditions
Name Ignorable
[100] mA Output 1 Saturated Yes
[110] Frequency Output 1 Saturated Yes
[113] mA Output 2 Saturated Yes
Frequency Input Saturated Yes
Frequency Output 2 Saturated Yes
mA Output 3 Saturated Yes
Process Aberration
Default severity: Out of Speculation
Severity configurable: Yes
Fault Timeout applicable: Yes
Table 7-13: Process Aberration conditions
Name Ignorable
[105] Two-Phase Flow Yes
[115] External Input Error Yes
[116] Temperature Overrange (API referral) Yes
[117] Density Overrange (API referral) Yes
[121] Extrapolation Alert (Concentration) Yes
[123] Pressure Overrange (API referral) Yes
[138] TBR Active Yes
Batch Time Out Yes
Moderate Two-Phase Flow Yes
Severe Two-Phase Flow Yes
Configure device options and preferences Configuration and Use Manual
March 2019 MMI-20025166
132 Micro Motion Model 5700 Transmitters with Configurable Outputs