Both Channel B and Channel D can be configured to act as Frequency Output 2. If you do this, the
Frequency Output 2 configuration will be applied to both channels.
Prerequisites
If you plan to configure the output to report volume flow, ensure that you have set Volume Flow Type as
desired: Liquid or Gas Standard Volume.
If you plan to configure an output to report a concentration measurement process variable, ensure that
the concentration measurement application is configured so that the desired variable is available.
Procedure
Set Frequency Output Source as desired.
Defaults:
Frequency Output 1: Mass Flow Rate
Frequency Output 2: Mass Flow Rate
Postrequisites
If you change the configuration of Frequency Output Source, verify the Frequency Output scaling. The
transmitter automatically loads the most recent values for the scaling parameters, and they may not be
appropriate for your application.
Related information
Configure Frequency Output Scaling
Options for Frequency Output Source
The transmitter provides a basic set of options for Frequency Output Source, plus several application-specific
options. Different communications tools may use different labels for the options.
Process variable
Label
Display PLIII FC
Standard
Mass flow rate Mass Flow Rate Mass Flow Rate Mass Flow Rate
Volume flow rate Volume Flow Rate Volume Flow Rate Volume Flow Rate
Gas standard volume flow
rate
GSV Flow Rate Gas Standard Volume Flow
Rate
GSV Flow Rate
Frequency Input flow rate FI Flow Rate Not available
Not available
API referral
Temperature-corrected
(standard) volume flow rate
Referred Volume Flow Volume Flow Rate at
Reference Temperature
Referred Volume Flow Rate
Concentration measurement
Standard volume flow rate Standard Vol Flow Volume Flow Rate at
Reference Temperature
Standard Volume Flow Rate
Net mass flow rate Net Mass Flow Net Mass Flow Rate Net Mass Flow (CM)
Integrate the meter with the control system Configuration and Use Manual
March 2019 MMI-20025166
150 Micro Motion Model 5700 Transmitters with Configurable Outputs