Method Description Setup
mA Input An external device sends
pressure data to the meter via
the mA Input.
a. Choose Configure > Manual Setup > Measurements >
Optional Setup > External Pressure/Temperature >
Pressure.
b. Set Pressure Compensation to Enable.
c. Choose Configure > Manual Setup > Inputs/Outputs >
Channel D.
d. Set Assignment to mA Input.
e. Choose mA Input > mA Input Settings.
f. Set Var Assignment to External Pressure.
g. Set Upper Range Value and Lower Range Value
appropriately.
h. Set Damping appropriately.
Digital
communications
A host writes pressure data to
the meter at appropriate
intervals.
a. Choose Configure > Manual Setup > Measurements >
Optional Setup > External Variables > External Pressure.
b. Set Pressure Compensation to Enable.
c. Perform the necessary host programming and
communications setup to write pressure data to the
transmitter at appropriate intervals.
Postrequisites
Choose Service Tools > Variables > Processand verify the values for External Temperature and External
Pressure.
Need help?
If the value is not correct:
Ensure that the external device and the meter are using the same measurement unit.
For polling:
Verify the wiring between the meter and the external device.
Verify the HART tag of the external device.
For the mA Input:
Verify the wiring between the meter and the external device.
Verify the power configuration for Channel D. If external power is required, ensure that the loop is
powered.
Verify the Lower Range Value and Upper Range Value settings for the mA Input.
Perform an mA Input trim.
Adjust the mA Input damping value.
For digital communications:
Verify that the host has access to the required data.
Configure process measurement applications Configuration and Use Manual
March 2019 MMI-20025166
68 Micro Motion Model 5700 Transmitters with Configurable Outputs

Table of Contents

Other manuals for Emerson Micro Motion 5700

Related product manuals